Anchor Windlass Control Box
XMS91 Series Anchor Control Box
The anchor windlass control box is used to control electrical anchors and windlass AC motor’s starting, stopping, and rotating. This marine control box protects against short circuits, defaults, overloads and voltage loss.
Application Environment:
Ambient temperature: -25℃- 45℃
Inclination, Swing: ±22.5°
There are influences of shock, vibration, salt mist, fungus and humid air on the sea when the ship is in normal operation.
The anchor control box can be single speed, double speed or three-speed depending on the motor. A three-speed control box should be used with a main controller. The protection class of the box is IP22 or IP44/IP56 depending on customer requirements.
Type of anchor control box and motor:
Data sheet of JZ2–H single speed marine motor
Control box type |
Rated operational current (A) |
Controlled motor |
Note |
Type |
Number of poles |
Rated power (KW) |
Rated current (A) |
XMS91 -16A |
16 |
JZ2-H-11 |
4 |
1.5 |
4.3 |
Conventional controller with remote control button box used to control clockwise and counterclockwise rotation. |
JZ2-H-12 |
4 |
22 |
60 |
JZ2-H-13 |
4 |
3.5 |
8.9 |
JZ2-H-21 |
4 |
5 |
12 |
JZ2-H-21 |
6 |
3.5 |
10 |
JZ2-H-22 |
6 |
5 |
13.3 |
XMS91 -25A |
25 |
JZ2-H-31 |
6 |
7.5 |
19.2 |
XMS91 -32A |
32 |
JZ2-H-32 |
6 |
11 |
26.8 |
XMS91 -40A |
40 |
JZ2-H-41 |
6 |
16 |
35 |
JZ2-H-41 |
8 |
11 |
28.9
|
Data sheet of JZ–H single speed marine motor
Control box type |
Rated operational current (A) |
Controlled motor |
Notes |
Type |
Number of poles |
Rated power (KW) |
Rated current (A) |
XMS91-16A |
16 |
YZ-112S-H |
4 |
1.5 |
4.3 |
Conventional controller with remote control button box used to control clockwise and counterclockwise rotation. |
YZ-112M-H |
4 |
2.2 |
6.0 |
YZ-112L-H |
4 |
3.7 |
9.6 |
YZ-112S-H |
6 |
1.1 |
3.5 |
YZ-112M-H |
6 |
1.5 |
4.65 |
YZ-112L-H |
6 |
22 |
6.6 |
YZ-132S-H |
6 |
3.7 |
10.5 |
YZ-132M1-H |
4 |
5.5 |
13.4 |
XMS91-25A |
25 |
YZ-132M- H |
6 |
5.5 |
15.3 |
YZ-132M2-H |
4 |
7.5 |
18.5 |
YZ-160S-H |
6 |
7.5 |
19.73 |
XMS91-32A |
32 |
YZ-160L-H |
6 |
11 |
26.8 |
XMS91-40A |
40 |
YZ-180L-H |
6 |
15 |
36
|
Data sheet of JZ2-H three-speed marine motor
Control box type |
Rated operational current (A) |
Controlled motor |
Matched master controller type |
Type |
Number of poles |
Rated power (KW) |
Rated current (A) |
XMS91-16/2 |
16 |
JZ2-H-22 |
4/12 |
3/1.2 |
6.8/7.2 |
LK911-117A |
JZ2-H-23 |
4/12 |
4.3/1.7 |
9.5/10.1 |
JZ2-H-32 |
4/12 |
6/2.5 |
12.9/11.3 |
XMS91-25/2 |
25 |
JZ2-H-33 |
4/12 |
8.5/3.5 |
17.9/14.8 |
JZ2-H-32 |
4/16 |
6/1.7 |
- |
JZ2-H-33 |
4/16 |
8.5/2.4 |
19.2/11.6 |
XMS91-40/2 |
40 |
JZ2-H-41 |
4/16 |
12/3.5 |
25.9/18.5 |
JZ2-H-42 |
4/16 |
18/5 |
37/23.8
|
Data sheet of JZ-H double-speed marine motor
Control box type |
Rated operational current (A) |
Controlled motor |
Matched master controller type |
Type |
Number of poles |
Rated power (KW) |
Rated current (A) |
XMS91 -16/2 |
16 |
YZ-112L-H |
4/12 |
Z2/0.75 |
6.575.4 |
LK911 一 117A |
YZ-132M-H |
4/12 |
3/1.1 |
8-7/7-6 |
YZ-132L-H |
4/12 |
4/1-5 |
10-3/9-1 |
XMS91 -25/2 |
25 |
YZ-160L-H |
4/12 |
6.3/Z2 |
15.4/12 |
YZ-180L-H |
4/12 |
8-5Z3-5 |
19.3/18 |
XMS91 -40/2 |
40 |
YZ-180L-H |
4/16 |
11/3 |
25/16.6 |
YZ-200M-H |
4/16 |
15/4 |
3Z8/24.1 |
XMS91 -63/2 |
63 |
YZ-200L-H |
4/16 |
18-5/5-5 |
40.4/3Z6
|
Data sheet of JZ2-H three-speed marine motor
Control box type |
Rated operational current (A) |
Controlled motor |
Matched master controller type |
Type |
Number of poles |
Rated power (KW) |
Rated current (A) |
XMS91 -32/3 |
32 |
JZ2-H-41 |
4/8/16 |
7.5/7.5Z5 |
16.8/17.8/26 |
LK911 一 110A |
XMS91 -40/3 |
40 |
JZ2-H-42 |
4/8/16 |
11/11/7 .5 |
23/25.3/38^ |
XMS91 -63/3 |
63 |
JZ2-H-51 |
4/8/16 |
16/16/11 |
33/35.2/49 |
XMS91 -100/3 |
100 |
JZ2-H-52 |
4/8/16 |
22/22/16 |
44/47.8/71 |
JZ2-H-61 |
4/8/16 |
30/30/22 |
60.5/69.5/96 |
XMS91 -160/3 |
100 |
JZ2-H-71 |
4/8/16 |
45/45/30 |
85.5/100/142 |
XMS91 -250/3 |
250 |
JZ2-H-72 |
4/8/16 |
60/60/45 |
114/135/196 |
XMS91 -400/3 |
400 |
JZ2-H-81 |
4/8/16 |
85/85/64 |
160/195/337
|
Data sheet of JZ-H three-speed marine motor
Control box type |
Rated operational current (A) |
Controlled motor |
Matched master controller type |
Type |
Number of poles |
Rated power (KW) |
Rated current (A) |
XMS91 -40/3 |
40 |
YZ-200S-H |
4/8/16 |
9/9/42 |
21.4/24.7/37.2 |
LK911-110A |
XMS91 "63/3 |
63 |
YZ-200L-H |
4/8/16 |
12.5/1Z5/5.7 |
29.3/34.3/49.5 |
XMS91 -100/3 |
100 |
YZ-225S-H |
4/8/16 |
16.8/16.8/8 |
38.9/46.2^7.6 |
YZ-225L-H |
4/8/16 |
2Z5/22.5/10.6 |
51.5^0.3/85.6 |
YZ-250S-H |
4/8/16 |
30/30/14.5 |
63.8/71.3/106.5 |
XMS91 -160/3 |
160 |
YZ-250M-H |
4/8/16 |
42/42/20 |
86-3/95/11Z6 |
YZ-280S-H |
4/8/16 |
66/66/27 |
114/120.6/147.5 |
XMS91 -250/3 |
250 |
YZ-280L-H |
4/8/16 |
75/75/36 |
164/161.5/182 |
XMS91 -300/3 |
300 |
YZ-315S-H |
4/8/16 |
100/100/48 |
198/209/303 |
XMS91 -400/3 |
400 |
YZ-315L-H |
4/8/16 |
135/135/65 |
267/282/410 |
Overall and mounting dimension of anchor control box:
Type |
H |
W |
D |
L3 |
L4 |
|
XMS91 -25A -32A-16A |
500 |
400 |
200 |
340 |
530 |
|
XMS91 -40A |
600 |
500 |
200 |
440 |
630 |
IP44
|
Type |
H |
W |
D |
LI |
L3 |
L4 |
|
XMS91 -16/2 -25/2 |
700 |
520 |
220 |
230 |
420 |
600 |
IP22 |
XMS91 -40/2 |
800 |
520 |
220 |
230 |
420 |
700 |
XMS91 -63/2 |
1000 |
550 |
280 |
290 |
450 |
900
|
Type |
H |
W |
D |
L1 |
L3 |
L4 |
|
XMS91 - 32/3 |
900 |
520 |
220 |
230 |
420 |
800 |
IP22 |
XMS91 -40/3 -63/3 |
1000 |
550 |
280 |
290 |
450 |
900 |
XMS91-100/3 |
1200 |
700 |
280 |
290 |
600 |
1100 |
IP22 |
XMS91-160/3 |
1200 |
700 |
280 |
290 |
600 |
1100 |
XMS91-250/3 |
1400 |
850 |
320 |
330 |
750 |
1300
|
Type |
H |
W |
D |
LI |
L3 |
L4 |
|
XMS91 -300/3 |
1800 |
950 |
350 |
160 |
890 |
250 |
IP44 |
XMS91 -400/3 |
1800 |
950 |
350 |
160 |
890 |
250 |
BXMS91 Series Explosion-Proof Marine Anchor Control Box
The BXMS91 series of explosion-proof anchor control boxes are used in shipping machinery where hazardous or explosive materials are present. The anchor windlass control box is used to control electrical anchors and windlass AC motor’s starting, stopping, and rotating and protects against short circuits, defaults, overloads and voltage loss.
Application Environment:
Ambient temperature:-25℃-45℃
Inclination, Swing: ±22.5°
There are influences of shock, vibration, salt mist, fungus and humid air on the sea when the ship is in normal operation.
Explosive gas atmosphere hazardous location: 1 district, 2 district
Steam level of inflammable gas: ‖A,‖B
Temperature classification: T1-T4
Explosion proof class : Exd‖BT4
Protection class: IP56
The motor’s auxiliary features and parameters are the same as the regular anchor control box.
Overall and Mounting Dimensions: